Window Techs brings to you the Fire-and-Smoke curtains in collaboration with clauss markisen (cm) Germany. For more than 50 years, now CM is a leading manufacturer of rolling textile special constractions for outside and inside shading-and-glare systems in the worldwide market. With fire-and smoke curtains, they sustain there tradition in rolling textile systems.

Fire and Smoke Curtains

Large View

Fire and Smoke Curtains

 

The cm constructions achieve a very high standard and all appropriate norms and regulations. Our systems can be easily assimilated in nearly all fire engineer concepts. For integration in the new or existing architecture we have a lot of experience due to our history.

 

For this reason we offer new appendage for smoke and fire protection comparing to existing systems. Intelligent solutions to reduce systems and fitting costs are possible and thus solve a lot of problems in the lot of preventive fire and smoke protection.

 


Fire and Smoke Curtains: Textile smoke & fire protection

Large View

Fire and Smoke Curtains: Textile smoke & fire protection

-Roll down to make the passage safe to exit

 

-Automatically activated by the signal from a   smoke or fire detector

 

-Safer than heavy and dangerous steel roller  shutters

 

-Works even on power failure

 

-Far less wear or tear and less maintenance than steel roller shutters

 

-Looks more attractive and do blend into the building structure

 

-Complying with and more that meets the existing fire regulations

 

-Can incorporate controls to allow the curtains to rise after activation

 

-2 to 4 hour integrity and fire resistance performance

 

-Tested for fire resistance from either or both directions

 

-Allow escape for occupants and entry for emergency services  through and under the curtain 24v operation with battery backup

 


Fire Creating A Safety Passage On Its Own .how

Large View

Fire Creating A Safety Passage On Its Own .how

Imagine fire in your building. When fire breaks, most of the casualties happen due to smoke poisoning. In such circumstances it is essential to guide  the smoke towards natural and mechanical

Extracting  systems or windows. This can be realized by moveable fire-and smoke curtains which divides industrial hall, airports, SHOPPING Centers and Parking Lots in defined Sub Arias so as to enable people find their  way to the emergency exits.

 

 

These curtains get activated by the signal from fire or smoke  detectors  or a building management system and automatically roll down, hence creating secured passage. The drop-down is done by Gravity fail- safe system without any electrical power supply. That means they also work in case of Electrical power  failure. Thus by using fire-and-smoke you can avoid those offer areas of  the building to get smoky. In a normal situation the systems are hidden in the parking position and can easily be integrated in the architecture.

 


Project :Hotel at Castle Garden, Stuttgart

Large View

Project :Hotel at Castle Garden, Stuttgart

Hotel at Castle Garden, Stuttgart

Architect: Baum Architects, Stuttgart, Mr. Schenk Client: LBBW Immobilien Development, Stuttgar Execution: 2010

Scope: 1 smoke-u.Brandschutzvorhang

Description: Fire curtain moved to separate hotel kitchen floor area

Width x Height 2300 mm x 2600 mm For optical reasons, the galvanized fire protection design completely covered with wood

 


Project :Hall 11, Frankfurt

Large View

Project :Hall 11, Frankfurt

Hall 11, Frankfurt         

 

General contractor: Max Bögl Construction GmbH & Co. KG Client: Messe Frankfurt AG Execution: 2009

 Circumference: 80 smoke curtains, 2,300 m²

 Description:Smoke curtains for dividing the building into defined sections smoke


Project :Medical center, Neumarkt

Large View

Project :Medical center, Neumarkt

Medical center, Neumarkt

Architect:    Theo Nutz, Neumarkt Client: The Doctors Neumarkt GmbH & Co. KG Execution: 2009

Range: 35 pieces of fire protection systems, about 330 m

Description:        Fire protection curtains to prevent flashover in the light wells and building internal corners


Project :Albert Magnus School, Viernheim

Large View

Project :Albert Magnus School, Viernheim

Albert Magnus School, Viernheim

Architect: PPS, waiters Krauss Stark GmbH Client: Bishop Ordninariat, Mainz Execution: 2008/2009

Size: 12 pieces of fire protection systems

Description:   Fire protection curtains on the division of the hall in different zones


Project :Hessischer Landtag, Wiesbaden

Large View

Project :Hessischer Landtag, Wiesbaden

Hessischer Landtag, Wiesbaden

Architect:    Waechter Waechter, Darmstadt Owner: Hessischer Landtag c / o B & S Consulting Execution: 2008

Size:     3 pieces of fire safety curtains, approx 60m 2

Description:    Fire protection curtains to prevent flashover between two fire areas

 


Project :Schwaben Galerie, Stuttgart

Large View

Project :Schwaben Galerie, Stuttgart

Schwaben Galerie, Stuttgart

Client:     HC Senator Rudy Haussler, Stuttgart Execution: 2005

Comprehensive fire protection:    about 700 m², 32 plants

Description:    Fire protection curtains in the garage to secure the external escape routes


Product---RST 73 Smoke Barrier Rigid

Large View

Product---RST 73 Smoke Barrier Rigid

RST 73 smoke barrier rigid

Size to 100 x 8 m
Classification: D60
Approval Z-78.9-75 and Z 56.4211-957
CE certified

 

Certificate: DIN EN 12101-1600 min ° C / 60.
Ears: glass filament fabric, non-flammable
DIN 4102-2 / A2 / Z 56429-930
Execution: hanging overlapping. Event profile in a trapezoidal shape, or round galvanized steel profile in Hemstitch 


Mounting: Ceiling mounting profile, steel galvanized


Product---RSS 74 Automatic Smoke Curtain

Large View

Product---RSS 74 Automatic Smoke Curtain

RSS 74 Automatic Smoke Curtain


Standard housing 150 x 150 mm
Plant size 6 x 3 m
Type: 1 ASB - ASB 2
Classification: D60
Approval Z-78.9-76 and Z 56.4211-957
CE certified

Certificate: DIN EN 12101-1600 min ° C / 60.
Ears: glass filament fabric, non-flammable
DIN 4102-2 / A2 / Z 56429-930
Version: free falling, and normally by gravity, the blinds overlap is possible
Drive: tubular motor standard 24 V or Failsafe
Tubular motor 230 V standard or failsafe
Mounting: ceiling, wall before, in the reveal



Product--RSR 75 Automatic smoke curtains

Large View

Product--RSR 75 Automatic smoke curtains

RSR 75 Automatic smoke curtains
raumabschliessend with roller guide


Standard housing 203 x 250 mm
in plant size 15 x 6 m,
max. Plant size on request

 

Type: 1 ASB - ASB 4
Classification: D60
Z 56.4211.957 CE certified

 

Certificate:  DIN EN 12101-1600 min ° C / 60.
Ears: glass filament fabric, non-flammable
DIN 4102-2 / A2 / Z 56429-930
Version: free falling, and normally by gravity,
Edged with side guide rails with roller guide
Drive: tubular motor standard 24 V or Failsafe
Tubular motor 230 V standard or failsafe
Flanschantrieb 400 V
Mounting: suspended from the ceiling, the ceiling, facing the wall, in the reveal


Product--  RSR 75.1 Automatic smoke curtains

Large View

Product-- RSR 75.1 Automatic smoke curtains

RSR 75.1 Automatic smoke curtains
raumabschliessend with roller guide


Standard housing 150 x 150 mm
in plant size 6 x 2.90 m

Type: 1 ASB - ASB 4
Classification: D60
Z 56.4211.957 CE certified

Certificate:  DIN EN 12101-1600 min ° C / 60.
Ears: glass filament fabric, non-flammable
DIN 4102-2 / A2 / Z 56429-930
Version: free falling, and normally by gravity,
Edged with side guide rail with baton
Drive: tubular motor standard 24 V or Failsafe
Tubular motor 230 V standard or failsafe
Flanschantrieb 400 V
Mounting: suspended from the ceiling, the ceiling, facing the wall, in the reveal


Product--  RSR 75.1 Automatic smoke curtains

Large View

Product-- RSR 75.1 Automatic smoke curtains

RSR 75.1 Automatic smoke curtains
raumabschliessend with roller guide

Standard housing    203 x 200 mm
in plant size 15 x 3.6 m
max. Plant size on request

Type: 1 ASB - ASB 4
Classification: D60
Z 56.4211.957 CE certified

Certificate: DIN EN 12101-1600 min ° C / 60.
Ears: glass filament fabric, non-flammable
DIN 4102-2 / A2 / Z 56429-930
Version: free falling, and normally by gravity,
Edged with side guide rail with baton
Drive: tubular motor standard 24 V or Failsafe
Tubular motor 230 V standard or failsafe
Flanschantrieb 400 V
Mounting: suspended from the ceiling, the ceiling, facing the wall, in the reveal



Contact us

Mr. Vishal Saraf (Director)
R. Z. - 335 / 13 - A, Tuglakabad Extension
New Delhi, Delhi - 110 019, India
Telephone:  +(91)-(11)-29992146/ 29992148/ Help Line No:- +91-9810073059

Contact via E-mail

Contact via Mobile

Contact via SMS

Member IndiaMART.com © Window Techs ( India) Pvt. Ltd.. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited