Window Techs ( India) Pvt. Ltd.Window Techs ( India) Pvt. Ltd.

Share:  


Home About Us Our Products Contact Us


Our Products



Home » Our Products » Fire Curtains

Fire Curtains

Supplier, Distributor and Manufacturer of Fire Curtain.Easy integration in any architecture prevention of fire flash-over smoke guiding in buildings protection of emergency exits


Fire Curtain-- Automatic Fire Safety Curtain

Fire Curtain-- Automatic Fire Safety Curtain


  • BSV 55.1 Automatic fire safety curtain,
  • space-final with baton
  • Standard housing 203 x 250 mm
    with system size 15 x 5 m
    max. Plant size on request and after approval

Classification: E30 - E180 / C2
Certificate: DIN 4102-2 1100 ° C / 180 min.
EN 1634-1 1100 ° C / 120 min. smoke-proof according to EN 12101-1
Ears: filament fabric with stainless steel, non-flammable
DIN 4102-2 / A2 / Z 56429-931
Design: free-fall, also energized by gravity, with side rails with baton in different versions
Drive: tubular motor or standard 24 V Failsafe
Tubular motor 230 V standard or fail safe
Mounting: suspended from the ceiling, the ceiling, facing the wall, in the reveal





Fire Curtain-- Automatic Fire Safety Curtain

Fire Curtain-- Automatic Fire Safety Curtain


  • BSV 55.1 Automatic fire safety curtain,
  • space-final with baton
  • Standard housing 150 x 150 mm
     in plant size 4 x 2.80 m

Classification: E30 - E180 / C2
Certificate: DIN 4102-2 1100 ° C / 180 min.
EN 1634-1 1100 ° C / 120 min. smoke-proof according to EN 12101-1
Ears: filament fabric with stainless steel, non-flammable
DIN 4102-2 / A2 / Z 56429-931
Design: free-fall, also energized by gravity, with the side chamfered guide with baton
Drive: tubular motor or standard 24 V Failsafe
Tubular motor 230 V standard or failsafe
Mounting: suspended from the ceiling, the ceiling, facing the wall, in the reveal





Fire Curtain-Automatic

Fire Curtain-Automatic


  • BSV 55 automatic fire curtain
  • Finally space with roller guide
  • Standard housing 203 x 250 mm
    with system size 15 x 6 m
    max. Plant size on request and after approval

Classification: E30 - E180 / C2
Certificate: DIN 4102-2 1100 ° C / 180 min.
EN 1634-1 1100 ° C / 120 min. smoke-proof according to EN 12101-1
Ears: filament fabric with stainless steel, non-flammable
DIN 4102-2 / A2 / Z 56429-931
Design: free-fall, also energized by gravity, with lateral guide rails with roller guides in different versions
Drive: tubular motor or standard 24 V Failsafe
Tubular motor 230 V standard or failsafe
Mounting: suspended from the ceiling, the ceiling, facing the wall, in the reveal





Fire Protection Curtains

Fire Protection Curtains


Albert Magnus School,

Viernheim Architect: KKS, waiters Krauss Stark GmbH

Client: Episcopal Ordninariat, Mainz Execution: 2008/2009 Size: 12 pieces of fire protection systems

Description: Fire curtains to delimit the hall into different fire areas



Fire Safety Curtain

Fire Safety Curtain


  • BSV 55 automatic fire curtain
              Standard housing 203 x 250 mm
  • BSV 55.1 Automatic fire safety curtain
               Standard housing150x150mm
  • BSV 55.1 Automatic fire safety curtain
               Standard housing 203 x 250 mm
  • Automatic fire sprinklers BSV curtain
               Standard housing 203 x 250 mm



Fire Safety Curtains

Fire Safety Curtains


Hessian State Parliament, Wiesbaden

Architect: Waechter Waechter +, Darmstadt
Client: Hessian State c / o B & S Consulting
Execution: 2008

Includes :3 piece fire curtains, approximately 60m 2

Description:

  • Fire curtains to avoid flashover between two fire zones




Fire Curtains

Fire Curtains

Window Techs brings to you the Fire curtains in India For more than 5 years, now  window techs is a leading manufacturer of rolling textile special constructions for outside and inside shading-and-glare systems in the worldwide market. With fire curtains, they sustain there tradition in rolling textile systems.






Automatic Fire Curtain

Automatic Fire Curtain


Imagine fire in your building. When fire breaks, most of the casualties happen due to smoke poisoning. In such circumstances it is essential to guide  the smoke towards natural and mechanical

Extracting  systems or windows. This can be realized by moveable fire-and smoke curtains which divides industrial hall, airports, Shopping Centers and Parking Lots in defined Sub Arias so as to enable people find their  way to the emergency exits.

These curtains get activated by the signal from fire or smoke detectors or a building management system and automatically roll down, hence creating secured passage. The drop-down is done by Gravity fail- safe system without any electrical power supply. That means they also work in case of Electrical power failure. Thus by using fire-and-smoke you can avoid those offer areas of the building to get smoky. In a normal situation the systems are hidden in the parking position and can easily be integrated in the architecture.

 









Contact Us
Window Techs ( India) Pvt. Ltd.
Mr. Vishal Saraf (Director)
R. Z - 335 / 13 - A, Tuglakabad Extension
New Delhi - 110019, Delhi, India

Contact via E-mail

Contact via SMS


Home  |  About Us  |  Our Products  |  Trade Offers (9)   |  Site Map  |  Contact Us

Member IndiaMART.com © Window Techs ( India) Pvt. Ltd.. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code: